Design and development of a portable potentiostat for electrochemical glucose detection in PBS solution

Authors

  • Bruno Ulises Godínez Davalos Tecnológico Nacional de México/Instituto Tecnológico de Tijuana/Posgrado en Ciencias de la Ingeniería, Blvd. Industrial 18881, Fraccionamiento Tecnológico (Mesa de Otay), C.P. 22430, Tijuana, Baja California, México https://orcid.org/0009-0000-2240-5576
    Competing Interests

    No conflict of interest declared

  • Reyna del Carmen Gutiérrez Gutiérrez Tecnológico Nacional de México/Instituto Tecnológico de Tijuana/Posgrado en Ciencias de la Ingeniería, Blvd. Industrial 18881, Fraccionamiento Tecnológico (Mesa de Otay), C.P. 22430, Tijuana, Baja California, México https://orcid.org/0009-0004-2136-4126
    Competing Interests

    No conflict of interest is declared.

  • José Ricardo Cárdenas Valdez Tecnológico Nacional de México/Instituto Tecnológico de Tijuana/Posgrado en Ciencias de la Ingeniería, Blvd. Industrial 18881, Fraccionamiento Tecnológico (Mesa de Otay), C.P. 22430, Tijuana, Baja California, México https://orcid.org/0000-0002-5437-8215
    Competing Interests

    No conflict of interest declared

  • Moisés Israel Salazar Gastélum Tecnológico Nacional de México/Instituto Tecnológico de Tijuana/Posgrado en Ciencias de la Ingeniería, Blvd. Industrial 18881, Fraccionamiento Tecnológico (Mesa de Otay), C.P. 22430, Tijuana, Baja California, México https://orcid.org/0009-0001-2996-8010
    Competing Interests

    No conflict of interest is declared.

  • Mara Beltrán Gastélum Tecnológico Nacional de México/Instituto Tecnológico de Tijuana/Posgrado en Ciencias de la Ingeniería, Blvd. Industrial 18881, Fraccionamiento Tecnológico (Mesa de Otay), C.P. 22430, Tijuana, Baja California, México https://orcid.org/0000-0002-3289-0664
    Competing Interests

    No conflict of interest is declared.

DOI:

https://doi.org/10.37636/

Keywords:

Biosensor, Electroanalysis techniques, Glucose, Potentiostat, Operational amplifier

Abstract

This work presents the design and implementation of a miniaturized portable potentiostat for electrochemical glucose detection applications. The proposed prototype is based on operational amplifier circuits and integrates three main stages: potential control, transimpedance amplification, and signal conditioning. The potential control stage maintains the required electrode polarization conditions, while the transimpedance amplifier converts the current generated by the biosensor into a measurable voltage signal. Experimental measurements were carried out using amperometric techniques on PBS solutions  with different glucose concentrations and a previously developed biosensor, comparing the performance of the prototype against a reference potentiostat. The acquired signals showed a linear response proportional to the glucose concentration (R² = 0.9939 prototype; R² = 0.9994 reference), with lower sensitivity in the proposed system (−0.0015 µA/µM) compared to the reference instrument (−0.0023 µA/µM). These results constitute an initial evaluation of the proposed architecture and support its potential use as a compact platform for portable electrochemical detection systems.

Downloads

Download data is not yet available.

References

[1] Federación Internacional de Diabetes, «Atlas de la Diabetes de la FID, 11.ª ed.,» Federación Internacional de Diabetes, Bruselas, 2025. Available: https://diabetesatlas.org/resources/idf-diabetes-atlas-2025/.

[2] J. Cole y J. Florez, «Genetics of diabetes mellitus and diabetes complications,» Nature Reviews Nephrology, vol. 16, nº 7, pp. 377-390, 2020, Available: 10.1038/s41581-020-0278-5.

[3] National Institute of Diabetes and Digestive and Kidney Diseases, «National Institute of Diabetes and Digestive and Kidney Diseases,» 2019. [En línea]. Available: https://www.niddk.nih.gov/health-information/informacion-de-la-salud/diabetes/informacion-general.

[4] Instituto Nacional de Estadística y Geografía (INEGI), «INEGI,» 18 septiembre 2026. [En línea]. Available: https://www.inegi.org.mx/contenidos/saladeprensa/boletines/2026/edr/EDR2026-1erT_RR.pdf.

[5] J. Wagner, C. Malchoff y G. Abbott, «Invasiveness as a barrier to self-monitoring of blood glucose in diabetes,» Diabetes Technology & Therapeutics, vol. 7, nº 4, pp. 612-619, 2005, doi: 10.1089/dia.2005.7.612.

[6] J. R. Sempionatto, J.-M. Moon y J. Wang, «Touch-Based Fingertip Blood-Free Reliable Glucose Monitoring: Personalized Data Processing for Predicting Blood Glucose Concentrations,» ACS Sensors, vol. 6, nº 5, 2021. doi: 10.1021/acssensors.1c00139.

[7] T. Soranzo, «Electrochemical biosensing of glucose based on the enzymatic reduction of glucose,» Sensors, vol. 22, nº 19, p. 7105, Sensors, doi: 10.3390/s22197105.

[8] J. Ahn, Y. Yang y G. Park, «Advancing elderly diabetes care: exploring the usability and acceptance of continuous glucose monitoring (CGM),» Geriatric Nursing, vol. 59, nº 19, pp. 15-25, 2024. doi: 10.1016/j.gerinurse.2024.06.041.

[9] R. A. Ajjan, T. Battelino, X. Cos, S. D. Prato, J. C. Philips, L. Meyer, J. Seufert y S. Seidu, «Continuous glucose monitoring for the routine care of type 2 diabetes mellitus,» Nature Reviews Endocrinology, vol. 20, nº 7, pp. 426-440, 2024, doi: 10.1038/s41574-024-00973-1.

[10] S. S. M. Ameen, K. M. Omer, F. R. Mansour, A. Bedair y M. Hamed, «Non-invasive wearable electrochemical sensors for continuous glucose monitoring,» Electrochemistry Communications, vol. 173, p. 107894, 2025.

[11] J. Kim, A. S. Campbell y J. Wang, « Wearable non-invasive epidermal glucose sensors,» Talanta, vol. 177, pp. 163-170, 2018, doi: 10.1016/j.elecom.2025.107894.

[12] X. Liping, Z. Zhibo, F. Mengdi y F. Xin, «Advances in wearable flexible electrochemical sensors for sweat monitoring: A mini-review.,» International Journal of Electrochemical Science., vol. 18, pp. 13-19, 2023, doi: 10.1016/j.ijoes.2023.01.009.

[13] M. Rashid, M. N. Aktar, V. Preda y N. Nasiri, «Advances in electrochemical sensors for real-time glucose monitoring,» Sensors & Diagnostics, vol. 3, nº 6, pp. 893-913, 2024, doi: 10.1039/d4sd00086b.

[14] R. Pallàs, Sensores y acondicionadores de señal, 4 ed., Marcombo, 2010. Avalible: https://books.google.com.pe/books?id=Eevyk28_fVkC&printsec=frontcover#v=onepage&q&f=false.

[15] D. Thévenot, K. Toth, R. Durst y G. Wilson, «Electrochemical biosensors: recommended definitions and classification,» Biosensors & Bioelectronics, vol. 16, pp. 121-131, 2001, doi: 10.1016/s0956-5663(01)00115-4.

[16] E. Torres y A. Méndez, «Biosensores enzimáticos,» Revista Digital Universitaria, vol. 15, nº 12, 2014, Avalible: https://www.revista.unam.mx/vol.15/num12/art97/art97.pdf.

[17] H. Duan, S. Peng, S. He, S.-Y. Tang, K. Goda, C. H. Wang y M. Li, «Wearable Electrochemical Biosensors for Advanced Healthcare Monitoring.,» Advanced Science., 2024.

[18] P. Shetti, S. Nayak, K. Reddy y M. Aminabhvi, «Graphene–Clay-Based Hybrid Nanostructures for Electrochemical Sensors and Biosensors.,» de Graphene-Based Electrochemical Sensors for Biomolecules., Elsevier Inc., 2019, pp. 235-274, doi: 10.1002/advs.202411433.

[19] Y. Wang, H. Xu, J. Zhang y G. Li , «Electrochemical Sensors for Clinic Analysis.,» Sensors, vol. 8, pp. 2043-2081, 2008, doi: 10.3390/s8042043.

[20] J. Baranwal, B. Barse, G. Gatto, G. Broncova y A. Kumar, «Electrochemical Sensors and Their Applications: A Review,» Chemosensors, vol. 10, nº 9, p. 363, 2022, doi: 10.3390/chemosensors10090363.

Schematic of a non-invasive system for measuring glucose in sweat.

Published

2026-11-25

Data Availability Statement

The data that support the findings of this study are available from the corresponding author upon reasonable request.

Issue

Section

Research articles

Categories

How to Cite

Godínez Davalos, B. U., Gutiérrez Gutiérrez, R. del C., Cárdenas Valdez, J. R. ., Salazar Gastélum, M. I. ., & Beltrán Gastélum, M. (2026). Design and development of a portable potentiostat for electrochemical glucose detection in PBS solution. Revista De Ciencias Tecnológicas, 9(4), 1-12. https://doi.org/10.37636/